|
|
|
 |
|

Continuous Power for
Mission Critical Applications
|
|
BENEFITS |
- True On-Line Technology
- Uncompromising Performance
- Reliability
- Communications
- Continuous Power When All Others Fail
- Off-the-shelf and Custom Solutions
|
|
|
|
|
|
INC
Technical brings you the first name in UPS reliability, Clary Corporation
UPS. Clary products offer True On-Line, Fully
Regenerative power solutions. You can find quality Clary systems in rugged
industrial applications, water and waste water works, hospitals, police and fire
emergency systems, oil fields, computer networks, traffic signals, and military
systems. Clary systems give you Stable, Advanced, Reliable, and Clean Power. About
Clary
Buy
Clary UPS Online Now
Clary Product Applications
What's New in the Clary Line?
MEDICAL PRODUCTS WITH UL 60601-1 LISTING.
UL listing 60601-1 replace the older UL 544 and UL 2601 listing that
defined requirements for electrical medical and dental equipment that is
intended for professional use by personnel in hospitals, nursing homes,
medical care centers, medical and dental offices and similar Health Care
Facilities. The UL 60601-1 listing will apply to Clary Corporation S
Series 1500Va products. |
|
|
|
|
|
|
|
The Clary Product Line... |
|
|
|
|
 |
|
CT
Series
Customizable UPS Systems 1250VA to 2400VA
The only On-Line Double
Conversion UPS system that offers selectable features to meet your
application needs. Wide selection of features such as input/output
isolation, switchable voltages or auto-sense capability, input circuit
breaker protection and input and output termination selection options.
Rugged design for applications in power plants, offshore drilling rigs,
refineries and shipboard use; can double as an electronic power
conditioner/frequency converter as well. All CT systems utilize Power
Factor Correction, and RS232 and SNMP protocols are supported. Available
in a 3U rack-mount configuration with extended battery options. Custom
configurations and engineering available. RATINGS: 1,250/1,500/ 2,000/2400
VA; various input and output voltages available. UL listed.
More about the CT Series... |

 |
|
DT
Series - Rack and Tower
Digital UPS Systems
1250VA to 2400VA/ 2000VA to 2400VA
The DT
Series features Clary’s On-Line Double Conversion, power factor corrected
technology for high reliability. Cash registers, POS Terminals,
workstations and communication equipment are typical applications that can
benefit from Clary’s UPS products. All DT Series Systems support RS232 and
SNMP protocols when communications back to the network are required.
Available in tower and rack-mount configurations with support for external
battery chassis when extended run-times are required. Custom
configurations available. Please consult factory. RATINGS: 1,250VA to
2,400VA / 2,000VA
to 2,400VA; 120/120 VAC; 50/60 Hz. UL listed.
• Small size – 3U racks, smallest in the industry
• Power factor Corrected to near unity
• Rackmount version fits into standard 19” rack
• Outputs can be controlled remotely or from front panel
• Software selectable configuration (output frequency, voltage, alarms,
auto turn-off, etc.)
• Automatic bypass and battery test
• Unit can also be cold started from batteries when no AC voltage is
present.
• Tower units include carrying handles
• Many options available for custom configurations. Consult factory.
More about the DT Series... |
|
 |
|
DT
Series - ET Rack and Tower
Digital UPS Systems for Extreme Conditions
-
40°C to +74°C
On-Line
Double Conversion technology at its best. For that application where all
others have failed due to extreme indoor or outdoor environmental
conditions. Operates at temperatures where others will not! Ideal for
those areas not environmentally controlled and in remote locations. All DT
Series ET systems utilize Power Factor Correction, and RS232 and SNMP
protocols are supported. Available in tower and rack-mount configurations
with extended battery run times. Custom configurations and engineering
available.
RATINGS: DT1,000R ET; 120/120 VAC; 50/60 Hz; -40°C to
+74°C. UL listed.
Harsh Environment Applications
Clary’s DT1000R(ET) is the world’s most advanced Uninterruptible Power
System (UPS) for extreme environment applications. The DT1000R(ET) keeps
equipment running for 10 minutes to 10 hours or more (dependent on
optional battery sizing) during power failures. Clary’s special Outpost™
batteries fit inside many existing cabinets and meet all NEMA temperature
specifications for outdoor use.
More about the DT ET Series... |
|
 |
|
GT
Series
Global UPS Systems
1000VA to 2400VA
The GT Series features
Clary’s On-Line Double Conversion, universal imput power factor corrected
technology for high reliability. Cash registers, POS Terminals,
workstations and communication equipment are typical applications that can
benefit from Clary’s UPS products. All GT Series Systems support RS232 and
SNMP protocols when communication back to the network are required..
Available in tower and rack-mount configurations with support for external
battery chassis when extended run-times are required. Custom
configurations available. Please consult factory. RATINGS:
1,250/1,500/2,000VA; 120/120 VAC; 50/60 Hz. UL listed.
• Power factor Corrected to near unity
• Outputs can be controlled remotely or from front panel
• Software selectable configuration (output frequency, voltage, alarms,
auto turn-off, etc.)
• Automatic bypass and battery test
• Unit can also be cold started from batteries when no AC voltage is
present.
• Tower units include carrying handles
• Many options available for custom configurations. Consult factory.
More about the GT Series... |
|
 |
|
RPS
Series
Digital UPS Systems for Extreme Temperature Rugged Applications /
Shipboard Grade
1250VA to 4000VA Unlike commercial
standby and hybrid UPS products, Clary's RPS Series products are designed
and built to rugged specifications. All systems are digitally
microprocessor controlled to provide clean, regulated power under all
tactical conditions. All RPS SERIES systems are Power Factor Corrected (PFC)
in real-time to ensure the highest possible efficiency. Full RS232 and
SNMP interactive communications capability assures support of all types of
command and control applications. 1,250/1,500/2,000/2,400 and 4000VA; 120
through 240 VAC input 45 to 65 Hz, 120 through 240VAC output; 50 or 60 Hz.
UL listed.
• Small size - 5.25” - 3U Rack Space
• Power Factor Corrected to near unity
• Rackmount version fits into standard 19” Rack
• Outputs can be controlled remotely or from front panel (Optional)
• Software selectable configuration (output frequency, voltage, alarms,
auto turn-off, etc.)
• Automatic bypass & battery test
• Unit can be started with out AC present (Cold Start)
• Many options available for custom configurations
• Transformer Isolation included
More about the RPS Series... |
|
 |
|
S
Series The Clary S Series UPS is
the only UPS of its class to offer medical grade performance. This
reliable power system is built to the highest quality standards. S Series
systems are typically found in patient care areas, medical laboratories,
nurse stations, medical or dental offices and are intended for non life
support applications.
• Keeps equipment running at all times
• Improves power quality
• Protects all connected equipment
• Easy installation in the office or lab environment
• No interrupted procedures
• Enhanced patient security
• No invalid test result
• No revenue disruption
More about the S Series |
|
 |
|
S603
Series Larger VA rated products
that also feature all-digital On-Line Double Conversion Technology.
Designed to provide maximum performance and reliability with Power Factor
Correction. Fully isolated output, and a wide range of input and output
voltage and frequency selection options are also available. Ideally suited
for server farms, telecommunication applications and many other
mission-critical applications where reliability is a must! Available in
Tower configuration. RATINGS: 6 kVA; input voltages of 208 and 240Vac are
standard and output voltages of 120/208/220/230/240 VAC; 50/60 Hz. UL
listed.
• True On-line Double Conversion
• Supports Redundant Parallel Architecture (RPA)
• Symmetrical or N+1 Capability
• Protects all connected equipment
• Superior Battery Management
• No interrupted procedures
• Enhanced patient security
• No invalid test result
• No revenue disruption
• Manual maintenance bypass switch
More about the S603 Series... |
|
   |
|
SP
Series
for Traffic Applications Keeping
intersections alive during power failures, Clary's SP Series is the
world’s most advanced Uninterruptible Power System (UPS) for traffic
applications. Without compromising existing cabinet wiring, the SP Series
keeps LED signal heads running for up to 8 hours or more during power
failures. Clary's continuous power systems fit inside most existing
cabinets and meet all NEMA temperature specifications. Optional NEMA 3R
Type II and Type III cabinets are available.
These systems also provide clean, regulated
power for controllers and other sensitive equipment inside the cabinet.
The SP1000SR/SN systems are intended for application where load usage will
not exceed 875 watts. These systems are also available with an extended
load option. The SP1250 SR/SN PLUS will allow for 1400 watts peak load for
a ten second interval. This option accommodates intersections that have
not yet replaced the yellow incandescent traffic lamps. Additionally,
Clary can provide a SP2000SR/SN system that will sustain a continuous 1400
watt load. These systems require eight batteries and additional cabinet
space or a separate cabinet such as the CBO-123 UPS cabinet.
Advanced communication features allow
monitoring, configuration and control of the system over RS232, modem or
network connections. Available for both NEMA and 332 style cabinets.
More
about the SP Series... |
|
 |
|
E603
Series
Larger VA rated products that also feature
all-digital On-Line Double Conversion Technology. Designed to provide
maximum performance and reliability with Power Factor Correction. Fully
isolated output, and a wide range of input and output voltage and
frequency selection options are also available. Ideally suited for server
farms, telecommunication applications and many other mission-critical
applications where reliability is a must! Available in Tower
configuration. RATINGS: 6 kVA; input voltages of 208 and 240Vac are
standard and output voltages of 120/208/220/230/240 VAC; 50/60 Hz. UL
listed.
• True On-line Double Conversion
• Supports Redundant Parallel Architecture (RPA)
• Symmetrical or N+1 Capability
• Protects all connected equipment
• Superior Battery Management
• No interrupted procedures
• Enhanced patient security
• No invalid test result
• No revenue disruption
• Manual maintenance bypass switch
More
about the E603 Series... |
|
|
 |
|
Traffic / ITS Solutions SP Series / SP-P/PD
Traffic application are challenging as they require UPS systems that
must function when needed and must perform flawlessly in environments
that go beyond the commercially available “run of the mill” offerings.
Clary UPS products are specifically designed for mission-critical
traffic applications where there is no room for error, when you just
can’t afford down time!
Problem:
Provide reliable field proven UPS systems for traffic control
applications.
Solution:
Clary SP Series products are listed by many states and DOT
requirements as the preferred UPS system for traffic intersection
back-up. Clary products are the only products engineered to meet NEMA
standards for traffic back-up systems with operational temperature range
of -40°C to +74°C. Clary SP Series is designed to mount in existing
traffic cabinets or in adjacent stand alone cabinets.
Result:
A superior traffic UPS system manufactured and tested to meet
the extreme requirements of traffic control systems.
More
about the
SP
Series / SP-P/PD... |
Standard Features:
Please Note:For the most current pricing or other sizes please
Contact US
| 120Vac Input |
CT & GT configured w/
Isolation Transformer |
NEMA 5-15P Input Cord on
1000 - 1500VA Models |
| Operating Temp. Range 0-40°C |
Frequency Sync Choices |
NEMA 5-20P Input Cord on
2000VA Models |
| RS-232 Port |
Open Collector/RS232
Outputs |
Bypass |
| Power Factor Control |
50/60Hz Output |
|
DT Series - Tower &
2U Rack Configurations
|
Model |
Rating |
Back-up Times
100%/50% |
Weight
LBS. |
Price* |
| DT1250 |
1250VA/875W |
7/21 |
42 |
$2,850 |
| DT1500 |
1500VA/1050W |
5/17 |
42 |
$3,200 |
| DT2000 |
2000VA/1400W |
5/18 |
55 |
$3,600 |
DT Series - Extreme Temperature
Options:
CT Series - 3U Rack Mount
Configurations w/ Isolation Transformer Standard
|
Model |
Rating |
Back-up Times
100%/50% |
Weight
LBS. |
List
Price* |
| CT1250R |
1250VA/875W |
12/25 |
79 |
$3,690 |
| CT1500R |
1500VA/1050W |
8/20 |
79 |
$4,050 |
| CT2000R |
2000VA/1400W |
6/22 |
92 |
$4,550 |
| CT2400R |
2400VA/1690W |
4.5/14 |
95 |
$4,990 |
GT Series - Tower Configurations
w/ Voltage Auto-Sense Transformer Standard
|
Model |
Rating |
Back-up Times
100%/50% |
Weight
LBS. |
List
Price* |
| GT1000 |
1000VA/700W |
5/17 |
55 |
$2,990 |
| GT1250 |
1250VA/857W |
7/21 |
80 |
$3,800 |
| GT1500 |
1500VA/1050W |
5/17 |
80 |
$4,100 |
| GT2000 |
2000VA/1400W |
5/18 |
100 |
$4,600 |
| GT2400 |
2400VA/1680W |
4.5/14 |
102 |
$5,100 |
CT Input Transformer Options:
| |
1000VA |
1250VA |
1500VA |
2000/2400VA |
1000VA |
1250-1500VA |
2000/2400VA |
|
Voltage Range |
PRICE* |
PRICE* |
PRICE* |
PRICE* |
OPTION# |
OPTION# |
OPTION# |
| 100/200 VAC, SWITCHABLE, ISOLATION |
90 |
120 |
190 |
210 |
CT-02B0 |
CT-02B1 |
CT-02B2 |
| 120/208 VAC, SWTICHABLE, ISOLATION |
90 |
120 |
190 |
210 |
CT-02C0 |
CT-02C1 |
CT-02C2 |
| 120/220 VAC, SWITCHABLE, ISOLATION |
90 |
120 |
190 |
210 |
CT-02D0 |
CT-02D1 |
CT-02D2 |
| 120/230 VAC, SWITCHABLE, ISOLATION |
90 |
120 |
190 |
210 |
CT-02E0 |
CT-02E1 |
CT-02E2 |
| 120/240 VAC, SWITCHABLE, ISOLATION |
90 |
120 |
190 |
210 |
CT-02F0 |
CT-02F1 |
CT-02F2 |
GT Series - Tower Configurations
w/ Voltage Auto-Sense Transformer Standard
| |
Price* |
Option Number |
| INPUT VOLTAGE AUTO SELECT |
$90 |
CT-04B |
| INPUT CIRCUIT BREAKER** |
$90 |
CT-04C |
**15 AMP for 1000-1500VA and 20 AMP for 2000-2400 VA
DT/CT/GT Input Plug
Options:
| |
|
1000-1500VA |
2000VA |
|
Type |
Price* |
Option Number |
Option Number |
| NEMA L5-15P |
$30 |
CT-05F |
N/A |
| NEMA L5-20P |
$30 |
N/A |
CT-05 |
| NEMA L6-15P |
$30 |
CT-05H |
N/A |
| NEMA L6-20P |
$30 |
N/A |
CT-05K |
| BS 1363 (UK & Ireland) |
$30 |
CT-05M |
N/A |
| CEE 7/7 (SCHUKO) |
$30 |
CT-05C1 |
CT-05C2 |
| Terminal Block/Hardwired (CT Only) |
$30 |
CT-05P |
CT-05P |
| Terminal Black/Hardwired (DT Only) |
$60 |
DT-05P |
DT-05P |
*All prices are U.S. Currency. INC Technical reserves the rights to change prices without
notice.
For the most current pricing or other sizes please
Contact Us
About Power
Why Be Concerned About
Power?
Methods of Power Protection
UPS 101
Types of UPS
Power Factor, Why is it
Important?
UPS Software / Connectivity

|
|
|